CODAN
Site language:  
Better than CODAN can only be CODAN
Home About us Equipment Dealers Contacts Order Site map
CODAN VSAT Transceivers
CODAN 8800
Digital Microwave Radio
CODAN Digital Microwave Radio
CODAN 8800 DMR Frequency Allocations and Band Plans
CODAN 8800 DMR
Network management principals
CODAN 8800 DMR
Forward error correction
CODAN 8800 DMR
Path Calculations
CODAN 8800 DMR
MINet overview
CODAN 8800 DMR
Antenna Solutions
CODAN 8800 DMR
Adjacent channel interference
CODAN 8800 series DMR
Technical Reference Manual
CODAN HF SSB Equipment
Search site:  
CODAN Digital Microwave Radio,DMR,Space Diversity,Redundancy

CODAN » Equipment » CODAN 8800 Digital Microwave Radio » CODAN Digital Microwave Radio
Printer-friendly versionPrinter-friendly version

CODAN Digital Microwave Radio



CODAN 8800 DMR Frequency Allocations and Band Plans
CODAN 8800 DMR Network management principals
CODAN 8800 DMR Forward error correction
CODAN 8800 DMR Path Calculations
CODAN 8800 DMR MINet overview
CODAN 8800 DMR Antenna Solutions
CODAN 8800 DMR Adjacent channel interference
CODAN 8800 series DMRTechnical Reference Manual

 Download Digital Microwave Radio 8800 series Reference Manual (1.7 MB)
 Download Digital Microwave Radio 8800 series Installation Handbook (330 KB)
 Download MINet Overview (160 KB)
 Download MINet Management Software User Guide (1.1 MB)

CODAN 8800 series - 7 GHz to 38 GHz

IDU Digital Microwave Radio CODAN 8800

ODU of Digital Microwave Radio CODAN 8800The CODAN 8800 series Digital Microwave Radio (DMR) provides 16 E1 (16 DS1), E3 (DS3), and 10/100BaseT ETHERNET transmission on an indoor unit and outdoor unit hardware platform. This is common across the entire frequency range from 7 GHz to 38 GHz.

This lightweight and rugged DMR delivers an exceptionally high grade of link performance particularly in difficult propagation conditions. In protected configurations, the CODAN 8800 offers 100% redundancy and uses advanced signal combining techniques to achieve exceptional link reliability.

The CODAN 8800 series digital microwave radios complies with the international standards for safety, spectrum emission and data transmission.

The product is software scalable and can be configured either locally or remotely. For large network roll-outs, installation can be undertaken by semi-skilled labour on site with commissioning by technical staff at a remote location.

All CODAN equipment is backed by a three year warranty and CODAN worldwide support network.

Key features

  • Adaptive Reed-Solomon Forward Error Correction (FEC) provides a high grade of service through high immunity to multi-path reflections.
  • Continuous Phase Modulation is robust and gives exceptional performance in high interference environments.
  • Adaptive Receiver Intermediate Frequency Control substantially reduces adjacent channel rejection.
  • Automatic Transmit Power Control (ATPC) and Remote Transmitter Power Control (RTPC) parameters are software controlled.
  • CODAN MINET, the Windows® based element manager, controls and monitors the network configuration via the SNMP Network Management Interface. CODAN MINET can control data transmission capacity and firmware upgrades throughout the network.
  • 100% equipment redundancy is featured in Hot Standby and Space Diversity configurations. Redundancy  switching  decisions are optimised for space diversity operation.

Data interfaces

Data Interface Units (DIU) Type

Interface requirements 4 Å1BNC

16 E1, E3
RJ 45

16 E1, E3
SCSI

16 DS1, DS3
RJ 45

16 DS1, DS3
SCSI

4xLAN
(Plus 4E1)

4xLAN
(Plus4DS1)

2/4 E1 (75 Ω)

+

           

2/4 E1 (120 Ω)

          +  

2/4/8/16 E1 (120 Ω)

  + +        

2/4/8/16 E1 (75 Ω)

    +        
E3 (75 Ω)   + +        

2/4 DS1 (100 Ω)

            +

2/4/8/16 E1 (100 Ω)

      + +    
DS3 (75 Ω)       + +    
4x10/100           + +
EOW

+

  +     + +
RS232

+

+ + + + + +
SNMP NMS

+

+ + + + + +
External I/O

+

+ + + + + +

CODAN network management

CODAN MINET is an intuitive, network management system with enhanced monitoring and diagnostic tools. It provides a simple graphical user interface to configure and manage local, remote and network radio terminals. Reporting of alarm status and statistical performance data further enhances CODAN MINET capability.

Because CODAN MINET is based on a standard SNMP platform it can be easily integrated with HP Open View.

The software enables proactive management of all links in a network from either single or multiple operator consoles running Microsoft Windows NT®, 98 or later.

Any Ethernet LAN attached management station running CODAN MINET can also be used to conveniently manage an IDU via the unit’s 10BaseT Ethernet management interface. SNMP management and cascading between IDU are standard features.

All radio links are easily controlled from the management station by either in-band or out-of-band signalling. IP Routers in each agent distribute the management information through the network to provide simultaneous management of all links from a single console. Inclusion of Trivial File Transfer Protocol (TFTP) capability enables remote site configuration and firmware upgrades.

With CODAN MINET definable alarm mapping capability, users can customize link and external alarm reporting criteria.

 

 

Redundant operation

The CODAN 8800 series digital microwave radio supports 100% redundancy in a 2RU solution with either single or dual antenna configurations.

Redundancy switching decisions are conditioned by parameters such as:

  • Link Status (fault condition)
  • User Definable Receive Signal Level
  • BER performance

The controlling algorithm provides hitless switching between the main and standby receiver paths. Space and frequency diversity operation is also supported.

A single antenna configuration requires the installation of an RF splitter. The splitter is optionally available as either:

  • an asymmetric split of 1.8 dB for the main branch and 6.5 dB split for the standby branch;
  • a symmetrical 3 dB split for both main and standby branches.
Technical specifications

System Parameters

7-8 GHz

10.5 GHz

13 GHz

15 GHz

18 GHz

23 GHz

26 GHz 38 GHz

ETSI

FCC ETSI ETSI   ETSI    ETSI FCC ETSI FCC ETSI ETSI FCC 

Frequency range

7.1-8.5 GHz

10.5–10.7 GHz

12.75-13.25 GHz 14.40-15.35 GHz 17.7-19.7 GHz 21.2-23.6 GHz 24.5-26.5 GHz 37.0-39.5 GHz 38.6-40 GHz

Tx–Rx duplex frequency

7.1-7.9 GHz
154 MHz
161 MHz
245 MHz

7.7-8.5 GHz
119 MHz
126 MHz
311.32 MHz

65 MHz
91 MHz

266 MHz 

315 MHz
420 MHz
490 MHz
644 MHz

1010 MHz 

1560 MHz

1008 MHz
1200 MHz
1232 MHz

1200 MHz

1008 MHz

1260 MHz

700 MHz 

RF interface

Slip fit, WR112
aperture
Slip fit, WR90
aperture
Slip fit, WR62
aperture
Slip fit, WR62
aperture
Slip fit, WR42
aperture
Slip fit, WR42
aperture
Slip fit, WR42
aperture
Slip fit, WR28
aperture

System gain
for BER=10-3

4E1 (4 DS1)
8E1 (8 DS1)
16E1 (16DS1)

115 dB
112 dB
109 dB

114 dB
111 dB
108 dB

114 dB
111 dB
108 dB

113 dB
110 dB
107 dB

 111 dB
108 dB
105 dB
107 dB
104 dB
101 dB

107.5 dB
104.5 dB
101.5 dB

107.5 dB
104.5 dB
101.5 dB

109 dB
105 dB
102.5dB

107.5 dB
104.5 dB
101.5 dB

101 dB
99 dB
96 dB

101.5 dB
98.5 dB
95 dB

Link ID security codes

10 000
programmable
codes

10 000
programmable
codes

10 000
programmable
codes

10 000
programmable
codes

10 000
programmable
codes

10 000
programmable
codes

10 000
programmable
codes

10 000
programmable
codes

Transmitter

Tx output power

+24 dB +27 dB +27 dB +25 dB +22 dB +22 dB +22 dB +19 dB

Software controlled output
power adjustment range

35 dB
in 1 dB steps

35 dB
in 1 dB steps

35 dB
in 1 dB steps

35 dB
in 1 dB steps

30 dB
in 1 dB steps

30 dB
in 1 dB steps

30 dB
in 1 dB steps

27 dB
in 1 dB steps

Tx mute level

< -45 dB < -45 dB < -45 dB < -45 dB < -45 dB < -45 dB < -45 dB < -45 dB

Frequency stability

±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm

Transmitter IF

400 MHz 400 MHz 400 MHz 400 MHz 400 MHz 400 MHz 400 MHz 400 MHz

Receiver

Frequency stability

±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm ±5 ppm

Receiver IF

140 MHz 140 MHz 140 MHz 140 MHz 140 MHz 140 MHz 140 MHz 140 MHz

Sensitivity
BER=10-3

4 E1/DS1
8 E1/DS1
16 E1/DS1 

-87 dB
-84 dB
-81 dB

-86 dB
-83 dB
-80 dB

-87 dB
-84 dB
-81 dB

-86 dB
-83 dB
-80 dB

-86 dB
-83 dB
-80 dB

-85 dB
-82 dB
-79 dB

-85.5 dB
-82.5 dB
-79.5 dB

-85 dB
-82 dB
-79 dB

-87 dB
-83 dB
-80.5 dB

-85 dB
-82 dB
-79 dB

-82 dB
-80 dB
-77 dB

-82.5 dB
-79.5 dB
-76 dB

Sensitivity
BER=10-6

4 E1/DS1
8 E1/DS1
16 E1/DS1

-84 dB
-81 dB
-78 dB

-83 dB
-80 dB
-77 dB

-84 dB
-81 dB
-78 dB

-83 dB
-80 dB
-77 dB

-83 dB
-80 dB
-77 dB

-82 dB
-79 dB
-76 dB

-82.5 dB
-79.5 dB
-76.5 dB

-82 dB
-79 dB
-76 dB

-84 dB
-81 dB
-79.5 dB

-82 dB
-79 dB
-76 dB

-80 dB
-77 dB
-74 dB

-79.5 dB
-76.5 dB
-73 dB

Maximum RF input level

0 dB 0 dB 0 dB 0 dB 0 dB 0 dB 0 dB 0 dB

Mechanical

IDU dimensions (1+0) 44.5mm (1RU) x 430mm x 305mm      
1.75" x 19" x 12" (H x W x D) 
IDU dimensions (1+1) 89mm (2RU) x 430mm x 305mm
3.5" x 19" x 12" (H x W x D)
IDU weight (1+0) 4.6 kg (1+1) 9.2 kg
(1+0) 10 lb (1+1) 20 lb
ODU dimensions (1+0)

230mm x 175mm
9" x 6.9" (Dia x H)

ODU dimensions (1+1)

230mm x 400mm
9" x 16" (Dia x H)

ODU weight (1+0) 4.9 kg (1+1) 11.3 kg
(1+0) 10.8 lb (1+1) 25.6 lb

Environmental

Altitude 4500m AMSL (15000 ft)
IDU temperature range –10°C to +45°C
IDU relative humidity

Up to 95% at +40°C

ODU temperature range

–55°C to +55°C

ODU relative humidity

Up to 100% all weather

IDU/ODU connection

Single 50 Ω coaxial cable of up to 300 meters (1000 ft) for each outdoor unit

Power requirements

Power source

±22 to 60 V DC

Power consumption 43W (1+0)
86W (1+1)

 

CODAN Digital Microwave Radio network management