VSAT C-Band Transceiver CODAN 5700 series,SSPA

CODAN » Equipment » CODAN VSAT Transceivers » VSAT C-Band » VSAT C-Band Transceiver CODAN 5700 series
Printer-friendly versionPrinter-friendly version

VSAT C-Band Transceiver CODAN 5700 series



VSAT C-Band Transceiver CODAN 5700 series  C-Band Transceiver 5700 series (CE) (5.2 MB)

CODAN 5700 series VSAT transceivers offer a wide range of distinctive advantages and enhanced features for satellite communications systems based in remote or challenging geographic regions.

Available in single or dual synthesizer options, standard or extended C-Band operation and 70 or 140 MHz IF configurations-and a range of power outputs-the CODAN 5700 provides industry leading technical performance.

Key features

Durability

The CODAN 5700 VSAT series transceiver  is designed and tested to meet its performance specifications in an ambient temperature range from -40°C to +55°C and up to 100% relative humidity, ensuring long-term survival in extreme conditions. The thermal protection provided allows operation up to +60°C ambient. Field experience shows that MTBF of greater than 100,000 hours can be expected.

RF performance

RF performance is superb, particularly: inter modulation performance, gain stability over temperature and flatness across the IF band. The CODAN 5700 VSAT transceiver also boasts industry leading spurious and harmonics specifications while guaranteed RF performance ensures expensive system link margins do not have to be used to cope with RF transceiver variations. The CODAN 5700 transceiver  high linearity and low spurious characteristics contribute to superior multi-carrier performance.

Output power options

Output ratings of 5, 10, 20, 30 and 40 watts are standard, while higher power options are also available.

Power consumption

CODAN VSAT C-Band transceivers all feature low power consumption and low temperature rise, ensuring internal components do not suffer undue stress. For example, the 5W system uses a maximum of 95 W, SSPA on, while the 30 W uses 220W maximum.

CODAN VSAT Redundancy switching system
CODAN VSAT 5700 transceivers antenna mounted in 1:1 configuration
Power supply

The CODAN VSAT 5700 transceiver features a 48 V DC floating input (37 V to 72 V range) with reverse polarity protection. This is ideal for battery backup and solar-powered systems. In addition, the CODAN  5700 VSAT transceivers  may be supplied with an optional AC power supply unit with field selectable 115/230 V operation.
The AC power supply unit is extremely robust and particularly suited for operation from poor quality AC supplies.

Internal protection

Internal  protection against high temperature and short or open circuit RF output is standard. As well, input voltage detection ensures reliable shutdown and restart under brownout or blackout conditions.

External protection

All  user access is via a transparent cover, which can be removed without exposing major internal electronics to the elements. Special sealant is used to ensure the sealing integrity of all connectors. RF modules are fully sealed and pressure tested to 34 kPa (5 psi). Particle and moisture penetration is rated to IP68 and the units are submersible to 3metres.

Advanced features

Enhanced monitor and control

All operating functions can be controlled and monitored via the serial interface. The operating configuration is stored in EEPROM to ensure the setup parameters are restored in the event of a power failure.

Universal interface compatibility

The CODAN 5700 VSAT transceiver  has universal interface compatibility capable of operating with dumb terminals, laptop/PC emulating terminals, hand-held terminals and personal organisers without requiring proprietary software. The versatile configuration options support: contact closure, RS232, RS422 and RS485 (2 or 4 wire).

Two dedicated controllers are available from Codan:

  • CODAN 5560 Hand-Held Controller, suitable for in the field installation setup
  • CODAN 5570 Remote Controller, suitable for indoor rack mounting to provide permanent monitoring and control capabilities

Redundancy switching system

A redundancy switching system is available to provide an automatic changeover to a second transceiver to maximise link availability and minimise any disruption to service. This system is fully outdoor mounted, but can be supplied with the 5587 Redundant System Monitor to provide indoor monitor and control.

CODAN VSAT 5560 Hand-held Controller CODAN VSAT 5570 controller

Major configuration options

Frequency bands* (MHz)

Transmit Receive
2 VSAT C-Band Extended

5850-6425

3625-4200

3 VSAT C-Band India

6725-7025 4500-4800

4 VSAT C-Band, Palapa-C, Thaicom-3, Intelsat VIII-A

6425-6725 3400-3700

Band 3 and 4 versions are not CE certified.

Transmit/receive frequency control

D Dual synthesiser

frequency bands 2 and 4

S Single synthesiser

frequency bands 2 and 3

Bandwidth

N Narrow band (40 MHz)

field selectable 70 or 140MHz IF

W Wide band (80MHz)

140MHz IF


SSPA output

N - N-type connector output

W - WR-137 waveguide output

 
M - SSPA monitor port

only available on 10 and 20W

LNAs 

A selection of LNAs is available to best meet noise temperature and configuration needs.

Options and accessories 

  • Hand-Held Controller
  • Remote Controller
  • Redundancy Switching System

CODAN quality and service

All CODAN C-Band VSAT transceivers are built and tested in CODAN  ISO9001 quality certified manufacturing facility, and undergo 100% burn in and performance monitoring over the temperature range specified.

CODAN fully trained staff and agents provide in-factory and in-country training services, and complete installation and on-site assistance. This service is backed up by a 24 hour customer service line and a warranty of three years on manufacturing, design or component defects.

Technical specifications

Transmit section

IF input

Frequency range

Narrow BW option
Wide BW option



70 + 20 MHz/140 + 20 MHz selectable
140 ± 40MHz

Impedance

50/75 Ω selectable

Connector

N-type female

Return loss 18 dB minimum at 50 Ω

Gain specification

Gain

5W
10W, 20W, 30W and 40W



71 dB nominal
74 dB nominal

Attenuator range

0 dB to 25 dB nominal

Attenuator step size

1 dB nominal

Gain flatness

Narrow BW option
Wide BW option


±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz
Gain stability

±1.5 dB maximum, -40°C to +55°C

RF output 

Frequency range

VSAT Band 2 (Extended)
VSAT Band 3 (Insat)
VSAT Band 4 (Palapa C & Intelsat VIII A)



5,850 - 6,425 GHz
6,725 - 7,025 GHz
6,425 - 6,725 GHz

Connector

N-type female, or CPR137-G (Band 2 only)

VSWR

1.5:1 maximum

5W CODAN VSAT SSPA

Output power (1 dB GCP)

+37 dBm minimum

Carrier to intermodulation ratio

-29 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP

10W CODAN VSAT SSPA

Output power (1 dB GCP)

+40 dBm minimum

Carrier to intermodulation ratio

-29 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP

20W CODAN VSAT SSPA

Output power (1 dB GCP)

+43 dBm minimum

Carrier to intermodulation ratio

-27 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP

30W CODAN VSAT SSPA

Output power (1 dB GCP)

+44.8 dBm minimum

Carrier to intermodulation ratio

-27 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP

40W CODAN VSAT SSPA

Output power (1 dB GCP)

+45.7 dBm minimum (+46 dBm typical)

Carrier to intermodulation ratio

-25 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP

Spurious output

Spurious output (including harmonics)

Meets EN301443 with 53 dBi antenna gain

Phase noise (SSB)**

100 Hz

-60 dBc/Hz maximum, -75 dBc/Hz typical

1 kHz

-70 dBc/Hz maximum, -80 dBc/Hz typical

10 kHz

-80 dBc/Hz maximum, -85 dBc/Hz typical

100 kHz -90 dBc/Hz maximum, -95 dBc/Hz typical

Synthesiser step size

Synthesiser step size

1MHz

Frequency stability

-40°C to +55°C

±2õ10-8

Aging

±1õ10-7/year

Receive section (excluding LNA)  

RF input

Frequency range

VSAT Band 2 (Extended)
VSAT Band 3 (Insat)
VSAT Band 4 (Palapa C & Intelsat VIII-À)



3,625 - 4,200 GHz
4,500 - 4,800 GHz
3,400 - 3,700 GHz

Impedance

50 Ω

Connector

N-type female

VSWR

1.4:1 maximum
Noise figure 18 dB typical
DC output (switch selectable)

+15 V @ 75 to 250mA

IF output 

Frequency range

Narrow BW option
Wide BW option



70 + 20 MHz/140 + 20 MHz selectable
140 + 40 MHz

Impedance

50/75 Ω selectable

Connector

N-type female

Return loss

18 dB minimum at 50 Ω

Gain specification

Gain

45 dB nominal

Attenuator range

0 dB to 30 dB nominal

Attenuator step size

1 dB nominal

Gain flatness

Narrow BW option
Wide BW option



±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz

Gain stability

±5.0/-4.0 dB maximum, -40°C to +55°C

Image rejection 50 dB minimum

Spurious output

-65 dBm maximum

Phase noise (SSB)**

100 Hz

-60 dBc/Hz maximum, -75 dBc/Hz typical

1 kHz

-70 dBc/Hz maximum, -80 dBc/Hz typical

10 kHz

-80 dBc/Hz maximum, -85 dBc/Hz typical

100 kHz

-90 dBc/Hz maximum, -95 dBc/Hz typical

Synthesiser step size

Synthesiser step size

1MHz

Frequency stability

-40°C to +55°C

±2õ10-8

Aging

±1õ10-7/year

Low noise amplifier

Indicative specifications; LNAs with lower noise temperatures are also available.

Input

Interface

CPR229-G

Noise temperature

40 K typical at 25°C

Gain specification

Gain

50 dB minimum

Output

1 dB GCP

+5 dBm minimum

Impedance

50 Ω

Connector

N-type female

VSWR 2.0 : 1 maximum

Transmit rejection filter (optional)

Indicative specifications.

TRFs to cover bands 2, 3 and 4 are available.

Insertion loss

0.05 dB maximum

Rejection

55 dB minimum

Monitor and control

LNA interface

DC output

+15 V @ 75 to 400 mA

Alarm input

Current monitoring as specified, and contact closure; O/C is fault condition

Control panel facilities

Indicators

Standby, On, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault.

Controls

Power control (off/standby/on), SSPA control (inhibit/remote/ activate), Serial interface settings, LNA supply via Rx RF Input connector, Mains/Battery supply select.

Remote monitor and control facilities

Serial interface standards

RS232, RS422 (RS485)

Protocol standards

ASCII, Packet (RS485)

Packet protocol address range 0 to 127

Remote monitoring functions (serial interface)

Standby, On, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault, SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive frequency*, Transmit attenuation*, Receive attenuation*, Cable compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm enable*, Fan alarm enable*, Temperature compensation*, Address*, SSPA mode*, Converter lock, Packet protocol*, IF impedance,*, IF frequency*, Power-up mode.

Remote control functions (serial interface)

Power control (standby/on), SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive frequency*, Transmit attenuation*, Receive attenuation*, Cable compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm enable*, Fan alarm enable, Temperature compensation select*, Address range*, SSPA mode*, Packet protocol*, IF impedance*, IF frequency*, Power-up mode.

All of the above serial interface functions are accessible via the Remote Controller 5570. The functions supported by the Hand-Held Controller 5560 are indicated by an *.

Remote monitoring functions (contact closure)

Standby, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault.

Remote control functions (contact closure)

Power control (standby/on), SSPA inhibit control, SSPA activate control.

Power

Input voltage

42 to 72 V DC (floating input) standard 115/230 V AC, +15% with Power Supply Unit

Power consumption

DC

5W
10W
20W
30W
40W



95W maximum SSPA On
160 W maximum SSPA On
200 W maximum SSPA On
220 W maximum SSPA On
280 W maximum SSPA On
40W maximum SSPA Off

AC

5W
10W
20W
30W
40W



150 VA maximum SSPA On
240 VA maximum SSPA On
310 VA maximum SSPA On
340 VA maximum SSPA On
370 VA maximum SSPA On
80 VA maximum SSPA Off

(all at nominal AC voltage)

Environmental

Converter module and SSPA module

Temperature

-40°C to +55°C

Relative humidity

100%

Cooling

Converter - Convection
5W - Convection
10 W, 20 W, 30 W and 40 W-Forced air

Weatherproofing

Sealed to 34 kPa

Power supply unit

Temperature

-40°C to +55°C

Relative humidity

100%

Cooling

Convection

Weatherproofing

Sealed to IP65

Physical

All dimensions are measured over the connectors.

Size

Converter module

110 mm W x 410 mm D x 240mm H

SSPA module, 5W

N-type output option
Waveguide output option



120 mm W x 370 mm D x 185mm H
120 mm W x 380 mm D x 185mm H

SSPA module, 10 W, 20 W, 30 W and 40W

N-type output option
Waveguide output option



165 mm W x 415 mm D x 215mm H
165 mm W x 420 mm D x 215mm H

Power Supply Unit

200 mm W x 160 mm D x 370mm H

Weight

Converter module

8 kg

SSPA module, 5 W

4.5 kg

SSPA module, 10 W, 20W, 30 W or 40W

9 kg

Power Supply Unit

10 kg