C-Band Transceiver 5700 series (CE) (5.2 MB)
CODAN 5700 series VSAT transceivers offer a wide range of distinctive advantages and enhanced features for satellite communications systems based in remote or challenging geographic regions.
Available in single or dual synthesizer options, standard or extended C-Band operation and 70 or 140 MHz IF configurations-and a range of power outputs-the CODAN 5700 provides industry leading technical performance.
Key features
Durability
The CODAN 5700 VSAT series transceiver is designed and tested to meet its performance specifications in an ambient temperature range from -40°C to +55°C and up to 100% relative humidity, ensuring long-term survival in extreme conditions. The thermal protection provided allows operation up to +60°C ambient. Field experience shows that MTBF of greater than 100,000 hours can be expected.
RF performance
RF performance is superb, particularly: inter modulation performance, gain stability over temperature and flatness across the IF band. The CODAN 5700 VSAT transceiver also boasts industry leading spurious and harmonics specifications while guaranteed RF performance ensures expensive system link margins do not have to be used to cope with RF transceiver variations. The CODAN 5700 transceiver high linearity and low spurious characteristics contribute to superior multi-carrier performance.
Output power options
Output ratings of 5, 10, 20, 30 and 40 watts are standard, while higher power options are also available.
Power consumption
CODAN VSAT C-Band transceivers all feature low power consumption and low temperature rise, ensuring internal components do not suffer undue stress. For example, the 5W system uses a maximum of 95 W, SSPA on, while the 30 W uses 220W maximum.
Power supply
The CODAN VSAT 5700 transceiver features a 48 V DC floating input (37 V to 72 V range) with reverse polarity protection. This is ideal for battery backup and solar-powered systems. In addition, the CODAN 5700 VSAT transceivers may be supplied with an optional AC power supply unit with field selectable 115/230 V operation.
The AC power supply unit is extremely robust and particularly suited for operation from poor quality AC supplies.
Internal protection
Internal protection against high temperature and short or open circuit RF output is standard. As well, input voltage detection ensures reliable shutdown and restart under brownout or blackout conditions.
External protection
All user access is via a transparent cover, which can be removed without exposing major internal electronics to the elements. Special sealant is used to ensure the sealing integrity of all connectors. RF modules are fully sealed and pressure tested to 34 kPa (5 psi). Particle and moisture penetration is rated to IP68 and the units are submersible to 3metres.
Advanced features
Enhanced monitor and control
All operating functions can be controlled and monitored via the serial interface. The operating configuration is stored in EEPROM to ensure the setup parameters are restored in the event of a power failure.
Universal interface compatibility
The CODAN 5700 VSAT transceiver has universal interface compatibility capable of operating with dumb terminals, laptop/PC emulating terminals, hand-held terminals and personal organisers without requiring proprietary software. The versatile configuration options support: contact closure, RS232, RS422 and RS485 (2 or 4 wire).
Two dedicated controllers are available from Codan:
- CODAN 5560 Hand-Held Controller, suitable for in the field installation setup
- CODAN 5570 Remote Controller, suitable for indoor rack mounting to provide permanent monitoring and control capabilities
Redundancy switching system
A redundancy switching system is available to provide an automatic changeover to a second transceiver to maximise link availability and minimise any disruption to service. This system is fully outdoor mounted, but can be supplied with the 5587 Redundant System Monitor to provide indoor monitor and control.
Major configuration options
|
Frequency bands* (MHz)
|
Transmit |
Receive |
| 2 VSAT C-Band Extended |
5850-6425
|
3625-4200
|
|
3 VSAT C-Band India
|
6725-7025 |
4500-4800 |
|
4 VSAT C-Band, Palapa-C, Thaicom-3, Intelsat VIII-A
|
6425-6725 |
3400-3700 |
Band 3 and 4 versions are not CE certified.
Transmit/receive frequency control
|
D Dual synthesiser
|
frequency bands 2 and 4 |
|
S Single synthesiser
|
frequency bands 2 and 3 |
Bandwidth
|
N Narrow band (40 MHz)
|
field selectable 70 or 140MHz IF
|
|
W Wide band (80MHz)
|
140MHz IF
|
SSPA output
| N - N-type connector output |
|
|
W - WR-137 waveguide output
|
|
| M - SSPA monitor port |
only available on 10 and 20W
|
LNAs
A selection of LNAs is available to best meet noise temperature and configuration needs.
Options and accessories
- Hand-Held Controller
- Remote Controller
- Redundancy Switching System
CODAN quality and service
All CODAN C-Band VSAT transceivers are built and tested in CODAN ISO9001 quality certified manufacturing facility, and undergo 100% burn in and performance monitoring over the temperature range specified.
CODAN fully trained staff and agents provide in-factory and in-country training services, and complete installation and on-site assistance. This service is backed up by a 24 hour customer service line and a warranty of three years on manufacturing, design or component defects.
Technical specifications
Transmit section
IF input
|
Frequency range
Narrow BW option
Wide BW option
|
70 + 20 MHz/140 + 20 MHz selectable
140 ± 40MHz
|
|
Impedance
|
50/75 Ω selectable
|
| Connector |
N-type female
|
| Return loss |
18 dB minimum at 50 Ω |
Gain specification
|
Gain
5W
10W, 20W, 30W and 40W
|
71 dB nominal
74 dB nominal
|
|
Attenuator range
|
0 dB to 25 dB nominal
|
|
Attenuator step size
|
1 dB nominal
|
Gain flatness
Narrow BW option
Wide BW option |
±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz |
| Gain stability |
±1.5 dB maximum, -40°C to +55°C
|
RF output
|
Frequency range
VSAT Band 2 (Extended)
VSAT Band 3 (Insat)
VSAT Band 4 (Palapa C & Intelsat VIII A)
|
5,850 - 6,425 GHz
6,725 - 7,025 GHz
6,425 - 6,725 GHz
|
|
Connector
|
N-type female, or CPR137-G (Band 2 only)
|
|
VSWR
|
1.5:1 maximum
|
5W CODAN VSAT SSPA
|
Output power (1 dB GCP)
|
+37 dBm minimum
|
|
Carrier to intermodulation ratio
|
-29 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
|
10W CODAN VSAT SSPA
|
Output power (1 dB GCP)
|
+40 dBm minimum
|
|
Carrier to intermodulation ratio
|
-29 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
|
20W CODAN VSAT SSPA
|
Output power (1 dB GCP)
|
+43 dBm minimum
|
|
Carrier to intermodulation ratio
|
-27 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
|
30W CODAN VSAT SSPA
|
Output power (1 dB GCP)
|
+44.8 dBm minimum
|
|
Carrier to intermodulation ratio
|
-27 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
|
40W CODAN VSAT SSPA
|
Output power (1 dB GCP)
|
+45.7 dBm minimum (+46 dBm typical)
|
|
Carrier to intermodulation ratio
|
-25 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
|
Spurious output
| Spurious output (including harmonics) |
Meets EN301443 with 53 dBi antenna gain
|
Phase noise (SSB)**
|
100 Hz
|
-60 dBc/Hz maximum, -75 dBc/Hz typical
|
|
1 kHz
|
-70 dBc/Hz maximum, -80 dBc/Hz typical
|
| 10 kHz |
-80 dBc/Hz maximum, -85 dBc/Hz typical
|
| 100 kHz |
-90 dBc/Hz maximum, -95 dBc/Hz typical |
Synthesiser step size
|
Synthesiser step size
|
1MHz
|
Frequency stability
|
-40°C to +55°C
|
±2õ10-8
|
|
Aging
|
±1õ10-7/year
|
Receive section (excluding LNA)
RF input
|
Frequency range
VSAT Band 2 (Extended)
VSAT Band 3 (Insat)
VSAT Band 4 (Palapa C & Intelsat VIII-À)
|
3,625 - 4,200 GHz
4,500 - 4,800 GHz
3,400 - 3,700 GHz
|
|
Impedance
|
50 Ω
|
|
Connector
|
N-type female
|
|
VSWR
|
1.4:1 maximum |
| Noise figure |
18 dB typical |
| DC output (switch selectable) |
+15 V @ 75 to 250mA
|
IF output
|
Frequency range
Narrow BW option
Wide BW option
|
70 + 20 MHz/140 + 20 MHz selectable
140 + 40 MHz
|
|
Impedance
|
50/75 Ω selectable
|
|
Connector
|
N-type female
|
|
Return loss
|
18 dB minimum at 50 Ω
|
Gain specification
|
Gain
|
45 dB nominal
|
|
Attenuator range
|
0 dB to 30 dB nominal
|
|
Attenuator step size
|
1 dB nominal
|
Gain flatness
Narrow BW option
Wide BW option |
±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz
|
| Gain stability |
±5.0/-4.0 dB maximum, -40°C to +55°C
|
| Image rejection |
50 dB minimum |
|
Spurious output
|
-65 dBm maximum
|
Phase noise (SSB)**
|
100 Hz
|
-60 dBc/Hz maximum, -75 dBc/Hz typical
|
|
1 kHz
|
-70 dBc/Hz maximum, -80 dBc/Hz typical
|
|
10 kHz
|
-80 dBc/Hz maximum, -85 dBc/Hz typical
|
| 100 kHz |
-90 dBc/Hz maximum, -95 dBc/Hz typical
|
Synthesiser step size
|
Synthesiser step size
|
1MHz
|
Frequency stability
|
-40°C to +55°C
|
±2õ10-8
|
|
Aging
|
±1õ10-7/year
|
Low noise amplifier
Indicative specifications; LNAs with lower noise temperatures are also available.
Input
|
Interface
|
CPR229-G
|
|
Noise temperature
|
40 K typical at 25°C
|
Gain specification
Output
|
1 dB GCP
|
+5 dBm minimum
|
|
Impedance
|
50 Ω
|
| Connector |
N-type female
|
| VSWR |
2.0 : 1 maximum |
Transmit rejection filter (optional)
Indicative specifications.
TRFs to cover bands 2, 3 and 4 are available.
|
Insertion loss
|
0.05 dB maximum
|
|
Rejection
|
55 dB minimum
|
Monitor and control
LNA interface
|
DC output
|
+15 V @ 75 to 400 mA
|
|
Alarm input
|
Current monitoring as specified, and contact closure; O/C is fault condition
|
Control panel facilities
|
Indicators
|
Standby, On, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault.
|
|
Controls
|
Power control (off/standby/on), SSPA control (inhibit/remote/ activate), Serial interface settings, LNA supply via Rx RF Input connector, Mains/Battery supply select.
|
Remote monitor and control facilities
|
Serial interface standards
|
RS232, RS422 (RS485)
|
|
Protocol standards
|
ASCII, Packet (RS485)
|
| Packet protocol address range |
0 to 127 |
Remote monitoring functions (serial interface)
Standby, On, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault, SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive frequency*, Transmit attenuation*, Receive attenuation*, Cable compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm enable*, Fan alarm enable*, Temperature compensation*, Address*, SSPA mode*, Converter lock, Packet protocol*, IF impedance,*, IF frequency*, Power-up mode.
Remote control functions (serial interface)
Power control (standby/on), SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive frequency*, Transmit attenuation*, Receive attenuation*, Cable compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm enable*, Fan alarm enable, Temperature compensation select*, Address range*, SSPA mode*, Packet protocol*, IF impedance*, IF frequency*, Power-up mode.
All of the above serial interface functions are accessible via the Remote Controller 5570. The functions supported by the Hand-Held Controller 5560 are indicated by an *.
Remote monitoring functions (contact closure)
Standby, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault.
Remote control functions (contact closure)
Power control (standby/on), SSPA inhibit control, SSPA activate control.
Power
|
Input voltage
|
42 to 72 V DC (floating input) standard 115/230 V AC, +15% with Power Supply Unit
|
Power consumption
|
DC
5W
10W
20W
30W
40W
|
95W maximum SSPA On
160 W maximum SSPA On
200 W maximum SSPA On
220 W maximum SSPA On
280 W maximum SSPA On
40W maximum SSPA Off
|
|
AC
5W
10W
20W
30W
40W
|
150 VA maximum SSPA On
240 VA maximum SSPA On
310 VA maximum SSPA On
340 VA maximum SSPA On
370 VA maximum SSPA On
80 VA maximum SSPA Off
|
|
(all at nominal AC voltage)
|
Environmental
Converter module and SSPA module
|
Temperature
|
-40°C to +55°C
|
|
Relative humidity
|
100%
|
|
Cooling
|
Converter - Convection
5W - Convection
10 W, 20 W, 30 W and 40 W-Forced air
|
| Weatherproofing |
Sealed to 34 kPa
|
Power supply unit
|
Temperature
|
-40°C to +55°C
|
|
Relative humidity
|
100%
|
|
Cooling
|
Convection
|
| Weatherproofing |
Sealed to IP65
|
Physical
All dimensions are measured over the connectors.
Size
|
Converter module
|
110 mm W x 410 mm D x 240mm H
|
|
SSPA module, 5W
N-type output option
Waveguide output option
|
120 mm W x 370 mm D x 185mm H
120 mm W x 380 mm D x 185mm H
|
|
SSPA module, 10 W, 20 W, 30 W and 40W
N-type output option
Waveguide output option
|
165 mm W x 415 mm D x 215mm H
165 mm W x 420 mm D x 215mm H
|
| Power Supply Unit |
200 mm W x 160 mm D x 370mm H
|
Weight
|
Converter module
|
8 kg
|
|
SSPA module, 5 W
|
4.5 kg
|
|
SSPA module, 10 W, 20W, 30 W or 40W
|
9 kg
|
| Power Supply Unit |
10 kg
|