CODAN 5700 series C-Band high power VSAT transceivers offer a wide range of distinctive advantages and enhanced features for satellite communications systems based in remote or challenging geographic regions.
Available in single or dual synthesizer options, extended VSAT C-Band frequency bands and 70 or 140MHz IF configurations-and a range of power outputs-the CODAN 5700 series high power VSAT transceivers provide industry leading technical performance.
Key features
Durability
The CODAN 5700 series high power VSAT transceivers are designed and tested to meet their performance specifications in an ambient temperature range from -40°C to +55°C, ensuring long-term survival in extreme conditions. Field experience shows that MTBF of greater than 60,000 hours can be expected.
RF performance
RF performance is superb, particularly intermodulation performance, gain stability over temperature and flatness across the IF band. These transceivers also boast industry leading spurious and harmonics specifications while guaranteed RF performance ensures expensive system link margins do not have to be used to cope with RF transceiver variations. The high linearity and low spurious characteristics contribute to superior multi-carrier performance.
Output power options
The CODAN 5700 series C-Band high power VSAT transceiver is available with 60 watts and 120 watts output power rating.
Power consumption
CODAN high power VSAT transceivers feature low power consumption and low temperature rise, ensuring internal components do not suffer undue stress.
Power supply
All the high power transceivers are AC mains powered and may be field selected to operate from either 115 V AC or 230 V AC.
Internal protection
Internal protection against high temperature and short or open circuit RF output is standard.
Advanced features
Enhanced monitor and control
All operating functions can be controlled and monitored via the serial interface, and the operating configuration is stored in EEPROM to ensure the set-up parameters are restored in the event of a power failure.
Universal interface compatibility
The CODAN 5700 series high power VSAT transceivers has universal interface compatibility capable of operating with dumb VSAT terminals, laptop/PC emulating terminals, handheld terminals and personal organizers without requiring proprietary software. The versatile configuration options support contact closure, RS232, RS422 and RS485 (2 or 4 wire).
Two dedicated controllers are available from CODAN:
- CODAN 5560 Hand-Held Controller, suitable for in the field installation setup
- CODAN 5570 Remote Controller, suitable for indoor rack mounting to provide permanent monitoring and control capabilities
Redundancy switching system
A redundancy switching system is available to provide an automatic changeover to a second VSAT transceiver to maximize availability and minimize any disruption to service. This system is fully outdoor mounted, but can be supplied with the CODAN 5587 Redundant System Monitor to provide indoor monitoring and control.
Major configuration options
|
VSAT C-Band frequency band (GHz)
|
Transmit |
Receive |
| 2 VSAT C-Band extended |
5.850-6.425
|
3.625-4.200
|
VSAT C-band transmit/receive frequency control
|
D - Dual synthesizer
|
|
S - Single synthesizer
|
Bandwidth
|
N - Narrow band (40MHz)
|
Field selectable 70 or 140MHz IF
|
|
W - Wide band (80 MHz)
|
140 MHz IF only
|
Output power
| VSAT C-Band |
60 W and 120W
WR137 waveguide output standard |
LNA
A selection of LNA is available to best meet noise temperature and configuration needs.
Options and accessories
- CODAN Hand-Held Controller
- CODAN Remote Controller
- CODAN Redundancy Switching Systems
- CODAN Transmit Reject Filters
- CODAN Antenna Mounting Kits
CODAN quality and service
The high power transceivers built and tested in CODAN ISO9001 quality certified manufacturing facility, and undergo 100% burn in and performance monitoring.
CODAN fully trained staff and agents provide in-factory and in-country training services and complete installation and on-site assistance. This service is backed up by a 24 hour customer service line and a warranty of three years on manufacturing, design or component defects.
Technical specifications
Transmit section
IF input
|
Frequency range
Narrow BW option
Wide BW option
|
70 + 20 MHz/140 + 20 MHz selectable
140 ± 40MHz
|
|
Impedance
|
50/75 Ω selectable
|
| Connector |
N-type female
|
| Return loss |
18 dB minimum at 50 Ω |
Gain specification
|
Gain
60 W, 120W
|
74 dB minimum
(0 dB SSPA & Converter attenuator settings)
|
|
Attenuator ranges
|
0 dB to 25 dB nominal (Converter)
0 dB to 20 dB nominal (SSPA)
|
|
Attenuator step size
|
1 dB nominal
|
Gain flatness
Narrow BW option
Wide BW option |
±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz |
| Gain stability |
±2.0 dB maximum, -40°C to +55°C
|
RF output
|
Frequency range
|
5.850–6.425 GHz
|
|
Connector
|
CPR137-G
|
|
VSWR
|
1.25:1 maximum
|
60W CODAN VSAT SSPA
|
Output power at 25°C
|
+47.8 dBm (60W) typical at saturation
+47.0 dBm minimum at 1 dB GCP
|
|
Carrier to intermodulation ratio
|
-26 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
|
120W CODAN VSAT SSPA
|
Output power at 25°C
|
+50.8 dBm (120 W) typical at saturation
+50.0 dBm minimum 1 dB GCP
|
|
Carrier to intermodulation ratio
|
-26 dBc, two carriers, each at 6 dB OPBO from 1 dB GCP
|
Spurious output
| Spurious output |
–60 dBc maximum at 1 dB GCP
|
Harmonics
| Harmonics |
–50 dBc maximum at 1 dB GCP
|
Phase noise (SSB)**
|
100 Hz
|
-60 dBc/Hz maximum, -75 dBc/Hz typical
|
|
1 kHz
|
-70 dBc/Hz maximum, -80 dBc/Hz typical
|
| 10 kHz |
-80 dBc/Hz maximum, -85 dBc/Hz typical
|
| 100 kHz |
-90 dBc/Hz maximum, -95 dBc/Hz typical |
Synthesiser step size
|
Synthesiser step size
|
1MHz
|
Frequency stability
|
-40°C to +55°C
|
±1õ10-8
|
|
Aging
|
±1õ10-7/year
|
Receive section (excluding LNA)
RF input
|
Frequency range
|
3.625 to 4.200 GHz
|
|
Impedance
|
50 Ω
|
|
Connector
|
N-type female
|
|
VSWR
|
1.4:1 maximum |
| Noise figure |
18 dB typical |
| DC output (switch selectable) |
+15 V @ 75 to 250mA
|
IF output
|
Frequency range
Narrow BW option
Wide BW option
|
70 + 20 MHz/140 + 20 MHz selectable
140 + 40 MHz
|
|
Impedance
|
50/75 Ω selectable
|
|
Connector
|
N-type female
|
|
Return loss
|
18 dB minimum at 50 Ω
|
Gain specification
|
Gain
|
45 dB nominal
|
|
Attenuator range
|
0 dB to 30 dB nominal
|
|
Attenuator step size
|
1 dB nominal
|
Gain flatness
Narrow BW option
Wide BW option |
±1.0 dB maximum, 40 MHz
±2.0 dB maximum, 80 MHz
|
| Gain stability |
±4.0 dB maximum, –40°C to +55°C
|
| Image rejection |
50 dB minimum |
|
Spurious output
|
-65 dBm maximum
|
Phase noise (SSB)**
|
100 Hz
|
-60 dBc/Hz maximum, -75 dBc/Hz typical
|
|
1 kHz
|
-70 dBc/Hz maximum, -80 dBc/Hz typical
|
|
10 kHz
|
-80 dBc/Hz maximum, -85 dBc/Hz typical
|
| 100 kHz |
-90 dBc/Hz maximum, -95 dBc/Hz typical
|
Synthesiser step size
|
Synthesiser step size
|
1MHz
|
Frequency stability
|
-40°C to +55°C
|
±1õ10-8
|
|
Aging
|
±1õ10-7/year
|
Low noise amplifier
Indicative specifications; LNAs with lower noise temperatures are also available.
Input
|
Interface
|
CPR229-G
|
|
Noise temperature
|
40 K at 25°C
|
Gain specification
Output
|
1 dB GCP
|
+5 dBm minimum
|
| 3rd order intercept |
+16 dBm minimum |
|
Impedance
|
50 Ω
|
| Connector |
N-type female
|
| VSWR |
1.5 : 1 maximum |
Transmit rejection filter (optional)
Indicative specifications.
|
Insertion loss
|
0.05 dB maximum
|
|
Rejection
|
55 dB minimum
|
Monitor and control
LNA interface
|
DC output
|
+15 V @ 75 to 400 mA
|
|
Alarm input
|
Current monitoring as specified, and contact closure; O/C is fault condition
|
Monitor and control facilities (converter)
|
Indicators
|
Standby, On, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, Fan fault.
|
|
Controls
|
Power control (off/standby/on), SSPA control (inhibit/remote/ activate), Serial interface settings, LNA supply via RX RF input connector, Mains/Battery supply select.
|
Monitor and control facilities SSPA
|
Indicators
|
Online, Alarm, Standby, Maintenance
|
|
Display
|
Output power, Heatsink temperature, Alarms
|
| Controls |
State, Gain, Compensation |
Remote monitor and control facilities (only via converter)
|
Serial interface standards
|
RS232, RS422 (RS485)
|
|
Protocol standards
|
ASCII, Packet (RS485)
|
| Packet protocol address range |
0 to 127 |
CODAN Remote monitoring functions (serial interface)
Standby, On, Warm-up, SSPA activated, Converter fault, LNA fault, SSPA fault, Temperature fault, SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive frequency*, Transmit attenuation*, Receive attenuation*, Cable compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm enable*, Fan alarm enable*, Temperature compensation*, Address*, SSPA mode*, Converter lock, Packet protocol*, IF impedance*, IF frequency*.
CODAN Remote control functions (serial interface)
Power control (standby/on), SSPA inhibit control, SSPA activate control*, Transmit frequency*, Receive frequency*, Transmit attenuation*, Receive attenuation*, Cable compensation*, Reference oscillator override*, SSPA alarm enable*, LNA alarm enable*, Fan alarm enable*, Temperature compensation select*, Address range*, SSPA mode*, Packet protocol*, IF impedance*, IF frequency*.
All of the above serial interface functions are accessible via the Remote Controller 5570. The functions supported by the Hand-Held Controller 5560 are indicated by an asterisk (*).
CODAN Remote monitoring functions (contact closure)
Standby, Warm-up, SSPA activated control, Converter fault, LNA fault, SSPA fault, Temperature fault.
CODAN Remote control functions (contact closure)
Power control, (standby/on), SSPA inhibit control, SSPA activate control.
Power
|
Input voltage
|
104 to 274 V AC, 47 to 63 Hz
|
Power consumption
|
AC
60W
120W
|
440 VA @ 115/230 V AC maximum SSPA On
760 VA @ 115/230 V AC maximum SSPA On
|
Environmental
Converter module
|
Temperature
|
-40°C to +55°C
|
|
Relative humidity
|
100%
|
|
Cooling
|
Convection
|
| Weatherproofing |
Sealed to IP68
|
SSPA module
|
Temperature
|
-40°C to +55°C
|
|
Relative humidity
|
100%
|
|
Cooling
|
Forced air
|
| Weatherproofing |
Sealed to IP66
|
Physical
All dimensions are measured over the connectors.
Size
|
Converter module
|
110 mm W x 410 mm D x 240 mm H
|
|
SSPA module, 60/120W
|
280 mm W x 355 mm D x 495 mm H
|
Weight
|
Converter module
|
8 kg
|
|
SSPA module, 60/120W
|
27 kg
|